- Max10: ADC no longer working with .pof file
- Draw Matter as the The fresh
- Draw Thing just like the Realize
- Float this subject having Newest Affiliate
We suspect you may have one to (or even more) a little slow otherwise lower than rated offers
I’m already dealing with Max10M16DAF256 and i struggle with this new ADC. sof document it really works fine. pof file the newest ADC doesn’t work any further, i.age ADC data is constantly zero, as anybody else areas functions accurately.
While using
I have and viewed that after coding with .pof file but still allow the suppy current towards the, the fresh new ADC works. But immediately after reset the production current (turn off and on once again), it will not performs any longer.
If the latter you will need to verify evaluate the method that you launch the newest ADC Internet protocol address from reset. Hold it from inside the reset ‘a little longer’ after the pump up. Sorry this could sound a tiny vague. That it appears to be an everyday point towards the discussion board you to does not appear to have obtained an obvious, legitimate provider.
Should this be your own panel then you will want to check on the above mentioned and make certain the rail go up monotonically. There are no sequencing criteria if the usually do not go up rightly – not fulfilling this new Tramp go out – the device have a tendency to misbehave. Relate to ‘Figure step 3. Monitored Electricity Offers Ramp Up’ regarding ‘ strength management affiliate publication (
In addition discover an identical issue with Max10 ADC in another thread, however, as if you told you there is no services for it.
The brand new panel is the care about build board. The issue is that many of our very own chatrooms work okay having ” .pof “-file, and some of these get this ADC state. To the forums with ADC problem, we investigated regarding the knowledge of them boards but unfortunately i didn’t find any problem with the hardware. Eg in the above list, new boards will work that have ” .sof ” and also ” .pof “-file when the also provide voltage is definitely with the. Pursuing the also provide voltage is actually reset, new ADC really does no further functions as the people is still operating accurately.
This makes me personally believe significantly more this matter are fuel relevant. You might be clearly into edge of no matter what concern is offered you’ve got working forums.
Do you really simply take a non doing work board, unplug the power provides and strength it out-of counter provides? My issue is one a lower than ranked railway actually around supplying the inrush called for and you will dips evoking the POR circuitry an excellent disease, hence (perhaps) isn’t really documented.
You’re best. I did specific study throughout the power offers to own Max10, and it seems like our very own analog likewise have requires slightly much time up until it is at complete current peak (we have been playing with Max10 dual likewise have product, and this need several electronic offers and you will step 1 analogue supply).
Like in Max10 Stamina management representative book, it looks like just the history power supply to have Max10 number (connected image), so we made an effort to swtich with the analog have very first and you will anticipate it to-arrive max height, following start the other two electronic supplies, and that need simply pair hundred s to-arrive maximum peak. It will help the perhaps not-operating ADC being working sporatically (not necessarily working).
But once i take an operating panel (ADC constantly functions) and you can perform some contrary succession (i.elizabeth help a couple of electronic offers on the first, then analogue supply), the fresh new ADC has been performing (i questioned which should not really works anymore).
So in some way the fresh new ADC condition makes reference to the benefit have succession as well as the ramp lifetime of strength supplies, however, an obvious reason for it disease might have been not receive but really.